testo 440 Probes & Accessories
£58.00 – £875.00
These IAQ probes are for the testo 440 IAQ instrument. The testo 440 probes are interchangeable with different measurement probe heads for maximum flexibility and cost saving. Open the “440 Probe System” tab below for an overview on how this system works.
Product Description
Use the testo 440 air velocity and IAQ measuring instrument in combination with high-quality probes to measure and store all air velocity and IAQ parameters. Up to 3 probes can be connected simultaneously: a Bluetooth probe, a wired probe and a temperature probe with type K thermocouple connector. Automatic probe detection and clearly structured measurement menus guarantee simple operation and will make your day-to-day work easier.
Measure in just a few clicks with the testo 440 multi-function measuring instrument
Carry out your measurements quickly and easily: the air velocity and IAQ measuring instrument automatically detects each connected probe. This means that there is no need for you to manually reset the parameters when changing probes. Clearly structured measurement menus for measuring the volume flow in ducts/at outlets, funnel measurement, measuring the degree of turbulence, determining the cooling/heating output, mold detection and long-term measurement provide you with optimum support during your day-to-day work.
Wireless and space-saving: more applications, less equipment
Endlessly versatile: a universal handle can be connected to all probe heads – so you can master more applications using less equipment and save space.
The Bluetooth handle makes it more convenient to carry out your measurement and guarantees less cable clutter in the case. It makes it possible to carry out measurements without any bothersome cable connection and it transfers readings up to a distance of 20 m. Or as a practical alternative, use the cable handle to connect testo probe heads. This is an advantage if Bluetooth signals are not permitted.
Practical measurement data management
The multi-function measuring instrument stores up to a max. 7500 measurement protocols, which can be read via a USB port and further processed as a CSV file on your computer (e.g. with Excel). With the testo BLUETOOTH/IRDA printer (please order separately), you have the option of producing a report printout of the measurement data directly on site.
Intelligent calibration concept for maximum precision
You can rely on accurate measurement results when using our digital probes, because the measuring instrument makes measurement uncertainty a thing of the past. You only need to send the probes in for calibration. The multi-function measuring instrument can therefore remain in continuous use.
Temperature – NTCHot wire probe (digital) including temperature sensor, wired: for measurements in ventilation ducts – measuring range 0 to 30 m/s, -20 to +70 °C |
|
Hot Wire Probe, Temperature & Humidity Sensor, Fixed CableHot wire probe (digital) including temperature and humidity sensor, wired: for measurements in ventilation ducts – measuring range 0 to +50 m/s, -20 to +70 °C, 5 to 95% RH |
|
Hot Wire Probe, Temperature & Humidity Sensor, BluetoothHot wire probe (digital) with Bluetooth® including temperature and humidity sensor: for measurements in ventilation ducts – measuring range 0 to +50 m/s, -20 to +70 °C, 5 to 95% RH |
|
16mm Vane Probe, Temperature Sensor, Fixed CableVane probe (Ø 16 mm, digital) including temperature sensor, wired: for measurements in ventilation ducts – measuring range +0.6 to +50 m/s, -10 to +70 °C |
|
16mm Vane Probe, Temperature Sensor, BluetoothVane probe (Ø 16 mm, digital) with Bluetooth® including temperature sensor: for measurements in ventilation ducts – measuring range +0.6 to +50 m/s, -10 to +70 °C |
|
High Precision 100mm Vane Probe, Temperature Sensor, Fixed CableHigh-precision vane probe (Ø 100 mm, digital) including temperature sensor, wired: for measurements at air outlets in cleanrooms, as well as at plate outlets, ventilation grilles or swirl outlets – measuring range +0.1 to +15 m/s, -20 to +70 °C |
|
High Precision 100mm Vane Probe, Temperature Sensor, BluetoothHigh-precision vane probe (Ø 100 mm, digital) with Bluetooth® including temperature sensor: for measurements at air outlets in cleanrooms and at plate outlets, ventilation grilles or swirl outlets – measuring range +0.1 to +15 m/s, -20 to +70 °C |
|
100mm Vane Probe, Temperature Sensor, Fixed CableVane probe (Ø 100 mm, digital) including temperature sensor, wired: for measurements at ceiling/air outlets and at plate outlets, ventilation grilles or swirl outlets – measuring range +0.3 to +35 m/s, -20 to +70 °C |
|
100mm Vane Probe, Temperature Sensor, BluetoothVane probe (Ø 100 mm, digital) including temperature sensor, Bluetooth: for measurements at ceiling/air outlets and at plate outlets, ventilation grilles or swirl outlets – measuring range +0.3 to +35 m/s, -20 to +70 °C |
|
High Precision Humidity & Temperature Probe, Fixed CableHigh-precision humidity/temperature probe (digital), wired: for measurements in cleanrooms and laboratories, and critical processes in the pharmaceutical, industrial and food sectors, as well as in storage, refrigerated and work rooms or in air conditioning/ventilation ducts – accuracy: ±(0.6% RH + 0.7 % of m.v.) (0 to 90% RH) / ±0.3 °C (+15 to +30 °C) |
|
High Precision Humidity & Temperature Probe, BluetoothHigh-precision humidity/temperature probe (digital) with Bluetooth®: for measurements in cleanrooms and laboratories, and critical processes in the pharmaceutical, industrial and food sectors, as well as in storage, refrigerated and work rooms or in air conditioning/ventilation ducts – accuracy: ±(0.6% RH + 0.7 % of m.v.) (0 to 90% RH) / ±0.3 °C (+15 to +30 °C) |
|
Humidity & Temperature Probe, Fixed CableHumidity/temperature probe (digital), wired: for measurements in rooms, ventilation ducts, refrigeration systems and heat pumps – accuracy ±2% RH / ±0.5 °C, measuring range 0 to 100% RH / -20 to +70 °C |
|
Humidity & Temperature Probe, BluetoothHumidity/temperature probe (digital) with Bluetooth®: for measurements in rooms, ventilation ducts, refrigeration systems and heat pumps – accuracy ±2% RH / ±0.5 °C, measuring range 0 to 100% RH / -20 to +70 °C |
|
Robust Humidity & Temperature ProbeRobust humidity/temperature probe (digital) for temperatures up to +180 °C, wired: for measurements in industrial exhaust air, in bulk materials and in climatic test cabinets – accuracy ±2% RH (2.1 to 98% RH) / ±0.4 °C (0.1 to +50 °C), measuring range 0 to 100% RH / -20 to +180 °C |
|
CO₂ Probe, Temperature & Humidity, Fixed CableCO₂ probe (digital) including temperature and humidity sensor, wired: for measuring the indoor air quality in offices, production areas or storage facilities – measuring range 0 to 10,000 ppm, -10 to +50 °C, 5 to 95% RH |
|
CO₂ Probe, Temperature & Humidity, BluetoothCO₂ probe (digital) with Bluetooth® including temperature and humidity sensor: for measuring the indoor air quality in offices, production areas or storage facilities – measuring range 0 to 10,000 ppm, -10 to +50 °C, 5 to 95% RH |
|
CO Probe, Temperature & Humidity, Fixed CableCO probe (digital), wired: for measuring carbon monoxide in indoor areas (e.g. boiler rooms) – measuring range 0 to 500 ppm |
|
CO Probe, Temperature & Humidity, BluetoothCO probe (digital) with Bluetooth®: for measuring carbon monoxide in indoor areas (e.g. boiler rooms) – measuring range 0 to 500 ppm |
|
Turbulence Probe, Fixed CableIndoor air turbulence probe, fixed cable Determine the degree of turbulence and draught risk according to EN ISO 7730 / ASHRAE 55. Measurement range: 0 to +5 m/s / 0 to +50 °C |
|
Fume Cupboard Probe, Fixed CableFume cupboard probe (digital), wired: for measuring inflow speed and exhaust air volume flow in fume cupboards according to DIN EN 14175-3/-4 – measuring range 0 to 5 m/s, 0 to +50 °C |
Hot Wire Probe HeadHot wire probe including temperature and humidity sensor: for measurements in ventilation ducts – measuring range 0 to +50 m/s, -20 to +70 °C, 5 to 95% RH |
|
16mm Vane Probe HeadVane probe head (Ø 16 mm, digital) including temperature sensor: for measurements in ventilation ducts – measuring range +0.6 to +50 m/s, -10 to +70 °C |
|
High Precision 100mm Vane Probe HeadHigh-precision vane probe head (Ø 100 mm, digital) including temperature sensor: for measurements at air outlets in cleanrooms and at plate outlets, ventilation grilles or swirl outlets – measuring range +0.1 to +15 m/s, -20 to +70 °C |
|
100mm Vane Probe HeadVane probe (Ø 100 mm, digital) including temperature sensor for measurements at ceiling/air outlets and at plate outlets, ventilation grilles or swirl outlets – measuring range +0.3 to +35 m/s, -20 to +70 °C |
|
High-precision Humidity/Temperature Probe HeadHigh-precision humidity/temperature probe head, for measurements in cleanrooms and laboratories, and critical processes in the pharmaceutical, industrial and food sectors, as well as in storage, refrigerated and work rooms or in air conditioning/ventilation ducts – accuracy: ±(0.6% RH + 0.7 % of m.v.) (0 to 90% RH) / ±0.3 °C (+15 to +30 °C) |
|
Humidity/Temperature Probe HeadHumidity/temperature probe head, for measurements in rooms, ventilation ducts, refrigeration systems and heat pumps – accuracy ±2% RH / ±0.5 °C, measuring range 0 to 100% RH / -20 to +70 °C |
|
CO₂ Probe HeadCO₂ probe including temperature and humidity sensor: for measuring the indoor air quality in offices, production areas or storage facilities – measuring range 0 to 10,000 ppm, -10 to +50 °C, 5 to 95% RH |
|
CO Probe HeadCO probe for measuring carbon monoxide in indoor areas (e.g. boiler rooms) – measuring range 0 to 500 ppm |
Cable Handle for testo 440 Probe HeadsCable handle for connecting probe heads: transmits readings to the testo 440 instrument via cable. Cable length: 1.4m. |
|
Bluetooth Handle for testo 440 Probe HeadsBluetooth handle for connecting probe heads: transmits readings to the testo 440 instrument Bluetooth. |
|
Handle Adapter for testo 440 Air Flow ProbesHandle adapter: for connection to air velocity probes with universal handle or extendable telescope for air velocity probes. |
|
Tripod for Comfort Level MeasurementMeasuring tripod for IAQ and comfort level measurements, consisting of folding stand, mounting rod, handheld instrument holder, 4 x probe mounts, including bag. |
|
Telescope Extenson for testo 440 Air Flow Probes (0.4, 0.9m)Telescope extension (consisting of 2 extension rods) for air velocity probes with universal handle, length 0.4 to 0.9 m. |
|
Extendable Telescope for testo 440 Air Flow Probes (1m incl 90° angle)Extendable Telescope for testo 440 Air Flow Probes (1m incl 90° angle), for air velocity probes with universal handle. |
|
90° Angle for 100mm Vane Probes90° angle: for the attachment of vane probes (Ø 100 mm) with universal handle: for correct positioning at ceiling outlets. |
|
Combi-Case for testo 440 and Multiple Probes
|
|
Transport Case for Volume Flow Measurement
|